Features of MEDISAFE WITHTM
MEDISAFE WITHTM is the first insulin patch pump in Japan.
Patients can administer insulin using remote control at hand, without attracting attention from others.
Since this patch is attached to the patient’s body, patients can enjoy fashion by freely choosing clothes to wear.
We value patients’ precious “time.” Just like a small partner, it always stays with patients.
- This small, lightweight tube-free model does not restrict patient’s daily activities
- Easy-to-understand, GUI designed touch panel remote control
- Simple operations that are easy to remember and use without hesitation
- Precise insulin administration
- Various settings to support treatment tailored to the patient’s life
- Product Specifications
This small, lightweight tube-free model does not restrict patient’s daily activitiesIt supports a life suitable for each patient.
It has been designed to pursue ease of use from the viewpoint of users.
It supports a life suitable for each patient.
Easy-to-understand, GUI designed touch panel remote controlA GUI* designed remote control displays icons that facilitate intuitive operations.
Bolus, basal rate, etc., are displayed with icons on the main menu screen. Patients can visually check the liquid delivery status.
*Graphical User Interface
Simple operations that are easy to remember and use without hesitationBecause it is used by patients, we pursue ease of use from the viewpoint of users.
Operations are easy to remember and easy to teach at the time of introduction.
Precise insulin administrationPatients can accurately control insulin administration by operating remote control.
“iCURADRIVE” is our unique technology that combines a smaller pump with precise delivery by 0.5 μL/h.
It controls accurate insulin administration.
It has adopted the same small motor drive principle as that used for digital cameras.
A dose can be precisely controlled per rotation angle according to the pulse signal.
The unique design enabled driving of the motor with the button battery, which contributed to the decrease in the pump size.
Various settings to support treatment tailored to the patient’s life
Dosing rate patterns can be set according to the patient’s activity levels
Patients can program up to three basal rates, according to their daily life patterns such as a workday/holiday, exercise, sick day, etc.
It allows patients to increase the dose by 0.05 U/h, and each pattern can be set by 30 minutes within 24 hours.
If temporary adjustment is necessary, for example for exercise, it can be set in “administration ratio (%)” or “administration rate (U/h).”
Select a bolus delivery mode according to the patient’s meals
Select from four modes of “Quick,” “Normal,” “Combination,” and “Long” according to the contents of meals.
It is equipped with a “bolus calculation function,” which can calculate an estimated bolus dose from the blood glucose level and carbs from a meal.
Bolus calculation function
Insulin dose is calculated by entering blood glucose level before a meal and carbs
-
1
Enter the blood glucose before a meal
-
2
Enter carbs
-
3
Insulin dose is calculated
※ Calculation results are examples
Setting: Carb ratio 10 g/u, insulin sensitivity factor 50 mg/dL/U
When the blood glucose target is 90-120 mg/dL
“Alert function” and “alarm function” for patient safety
An alert function (low emergency) and an alarm function (high emergency) are equipped to inform patients of trouble and how to deal with it.
It also has a convenient anti lost alarm function, which informs patients when the distance between the pump and remote control exceeds 1.5 meters.
An alert can be set at designated intervals according to the patient’s life style.
Product Specifications
Find details of MEDISAFE WITH components and specification table here.